* Rectangular design triple walled horizontal autoclave mounted on a sturdy, heavy M.S.
duly painted tubular stand
* Inner chamber, door lid, jacket, boiler & outer jacket cover made of SS 304 Chamber is
rectangular in shape with crevice free smooth rounded corners.
* Single hinged door and manual radial locking system
* Steam is generated in a separate boiler which is placed below the main body
* Lid is made of S.S. plate provided with pressure locking system which prevents opening
of the door while Steam is inside the chamber
* Industrial grade energy efficient heaters reduce power bills drastically
* Gap between Jacket and outer cover wall is filled with high grade fiber/mineral glass
wool insulation
* Fitted with pressure gauge for jacket, compound gauge for chamber, spring loaded
safety valveand separate manual steam release ball valvefor jacket and chamber.
* Automatic Vacuum Breaker is provided to break the vacuum in case of formation of
vacuum due to steam condensation.
* Automatic Pressure Control Switch for over pressure safety. When steam pressure
inside jacket reaches 18 to 20 psi it automatically cuts off electric supply to heater.
* Automatic Low Water Level Cut-off Device fitted for general safety of heating element
* Digital PID temperature indicator cum controller - Controller has LCD display which
displays set value and process value. It has inbuilt automatic digital minute Timer
which starts automatically when set/desired value of temperature is achieved. When
the set time period is over heaters get switched off automatically with alarm for cycle
end.
* For ensuring proper sealing of the door with the chamber and zero leakage a high
tensile joint less Silicon gasket is used which is seated in an integrated groove
* SS Baffle plate for effective steam distribution and avoid direct hitting of steam on
sample load
* Validation port provided
* Chamber Condensate Line is incorporated with steam trap for perfect condensation to
get optimum temperature
* Fitted with plug screen to prevent line choking due to sediment discharge
* Autoclave is fitted with water level indicator glass gauge and easily replaceable
heaters
* Manually operated multiport valve having 4 positions is provided for Steam injection
inside the chamber, dry sterilization & steam exhaust.
* Inner chamber & outer jacket is made of 14 SWG
* Hydraulically tested at 40psi 2.5 times the operating pressure of autoclave
* Small sized autoclave works on 230V single phase power supply and big size works
efficientlyon 440V three phase power supply
|