QUARTZ DISTILLATION APPARATUS APS-194


APPLICATIONS & ADVANCED FEATURES

  • The water distillate from Quartz Single/Double Distillation apparatus is beyond compare with water distillate obtained from other types/method of distillation apparatus.
  • Pyrogen free distillate obtained which is free of heavy metals.
  • Instant distilled water flow.
  • Quartz boiler (SiO2) is chemically inert to most solvents and acids, hence purer distillate.
  • No heat loss in the boiler, hence saves electrical power.
  • High performance with low maintenance.
  • Compact design with all contact of water with High Pure Electronic Grade Transparent Quartz only.
  • The main unit has got a bottom boiler and top boiler with condenser, which can be easily separated (Demountable) for necessary cleaning or maintenance. A bottom vent is provided in bottom boiler for general cleaning and maintenance.
  • The main constituent of Quartz is SiO2>99.9%, which makes the apparatus highly resistant to any thermal shock, devitrification and resistant to water and acids.
  • The electrical heaters are so designed, they do not come into contact with water, because they are embedded inside a quartz tube, hence nullifying the possibility of metal contamination by the heater.
  • The distillate obtained from this apparatus is PYROGEN FREE, it is also free from metal ions.
  • Demountable ball joint.
  • Spiral heaters has better life span than tubular sheathead heater.

SINGLE STAGE QUARTZ DISTILLATION WITH QUARTZ BOILER & CORNING CONDENSER

MODEL (SINGLE STAGE) #APS-10SS #APS-15SS #APS-20SS #APS-25SS
OUTPUT CAPACITY 1.0 ltrs/hr 1.5 ltrs/hr 2.0 ltrs/hr 2.5 ltrs/hr
BIOLOGICAL PURITY Pyrogen Free
CONDUCTIVITY 1.5-3.0 µS/cm
DISTILLATE TEMPERATURE 500C-600C+50C
SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
ELECTRIC SUPPLY 220/240 V AC

MODEL (SINGLE STAGE) #APS-30SS #APS-40SS #APS-50SS
OUTPUT CAPACITY 3.0 ltrs/hr 4.0 ltrs/hr 5.0 ltrs/hr
BIOLOGICAL PURITY Pyrogen Free
CONDUCTIVITY 1.5-3.0 µS/cm
DISTILLATE TEMPERATURE 500C-600C+50C
SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
ELECTRIC SUPPLY 220/240 V AC

DOUBLE STAGE QUARTZ DISTILLATION WITH QUARTZ BOILER & CORNING CONDENSER


MODEL (DOUBLE STAGE) #APS-10DS #APS-15DS #APS-20DS #APS-25DS
OUTPUT CAPACITY 1.0 ltrs/hr 1.5 ltrs/hr 2.0 ltrs/hr 2.5 ltrs/hr
BIOLOGICAL PURITY Pyrogen Free
CONDUCTIVITY 1.5-3.0 µS/cm
DISTILLATE TEMPERATURE 600C-750C+50C
SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
ELECTRIC SUPPLY 220/240 V AC

MODEL (SINGLE STAGE) #APS-30DS #APS-40DS #APS-50DS
OUTPUT CAPACITY 3.0 ltrs/hr 4.0 ltrs/hr 5.0 ltrs/hr
BIOLOGICAL PURITY Pyrogen Free
CONDUCTIVITY 1.5-3.0 µS/cm
DISTILLATE TEMPERATURE 60oC-75oC+5oC
SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
ELECTRIC SUPPLY 220/240 V AC

OPTION

  • LWCO - Low Water Level Cut-off Device for general safety of the heating system

  • SINGLE STAGE QUARTZ DISTILLATION WITH QUARTZ BOILER & QUARTZ CONDENSER


    MODEL (SINGLE STAGE) #APS-10FF #APS-15FF #APS-20FF #APS-25FF
    OUTPUT CAPACITY 1.0 ltrs/hr 1.5 ltrs/hr 2.0 ltrs/hr 2.5 ltrs/hr
    BIOLOGICAL PURITY Pyrogen Free
    CONDUCTIVITY Less than 0.1 µS/cm
    STAGES Available in Single or Double Stage (as ordered)
    DISTILLATE TEMPERATURE 600C-750C+50C
    SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
    ELECTRIC SUPPLY 220/240 V AC

    MODEL (SINGLE STAGE) #APS-30FF #APS-40FF #APS-50FF
    OUTPUT CAPACITY 3.0 ltrs/hr 4.0 ltrs/hr 5.0 ltrs/hr
    BIOLOGICAL PURITY Pyrogen Free
    CONDUCTIVITY Less than 0.1 µS/cm
    STAGES Available in Single or Double Stage (as ordered)
    DISTILLATE TEMPERATURE 600C-750C+50C
    SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
    ELECTRIC SUPPLY 220/240 V AC

    DOUBLE STAGE QUARTZ DISTILLATION WITH QUARTZ BOILER & QUARTZ CONDENSER


    MODEL (DOUBLE STAGE) #APS-10FS #APS-15FS #APS-20FS #APS-25FS
    OUTPUT CAPACITY 1.0 ltrs/hr 1.5 ltrs/hr 2.0 ltrs/hr 2.5 ltrs/hr
    BIOLOGICAL PURITY Pyrogen Free
    CONDUCTIVITY Less than 0.1 µS/cm
    STAGES Available in Single or Double Stage (as ordered)
    DISTILLATE TEMPERATURE 600C-750C+50C
    SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
    ELECTRIC SUPPLY 220/240 V AC

    MODEL (SINGLE STAGE) #APS-30FS #APS-40FS #APS-50FS
    OUTPUT CAPACITY 3.0 ltrs/hr 4.0 ltrs/hr 5.0 ltrs/hr
    BIOLOGICAL PURITY Pyrogen Free
    CONDUCTIVITY Less than 0.1 µS/cm
    STAGES Available in Single or Double Stage (as ordered)
    DISTILLATE TEMPERATURE 600C-750C+50C
    SAFETY (OPTION) Low water cut off device for safety of the heating element.(Option)
    ELECTRIC SUPPLY 220/240 V AC

    OPTION

  • LWCO - Low Water Level Cut-off Device for general safety of the heating system.